Dynamic Monitoring of Flue Gas Composition During Clean Coal Combustion in Industrial Boiler

李震宇,程军,刘建忠,刘雪松,宋玉彩,曹欣玉,岑可法
DOI: https://doi.org/10.3969/j.issn.1005-006x.2002.04.001
2002-01-01
Abstract:The advanced performance of testo360 system in flue gas complete analysis and online monitoring is analyzed by comparison. The dynamic characteristics of flue gas composition are monitored in 4t/h and 10t/h traveling-grate boilers. It is found that the dynamic peak and vales of SO2 concentration are opposite to those of O2. The time trace of NO concentration is similar to that of SO2, but meanwhile it is also affected by CO concentration. For the furnace temperature in industrial boilers is generally above 1200℃, the SO2 concentration in flue gas is mainly determined by the sulfur content in coal and desulfurization technology.
What problem does this paper attempt to address?