Distribution characteristics of minor and trace elements in fine particulate matters from a 660 MW coal-fired boiler
wang chao,liu xiaowei,xu yishu,wu jianqun,wang jianpei,xu minghou,lin xianmin,li haishan,xia yongjun
DOI: https://doi.org/10.3969/j.issn.0438-1157.2013.08.039
2013-01-01
Abstract:Sampling system with Dekati Gravimetric Impacter(DGI)was positioned in front of the 2# boiler ESP of a power plant in Nanchang and used to collect PMs,while the samples of raw coal and bottom ash were also taken.The massive particle size distribution of fly ash,the distribution characteristics of minor and trace elements in bottom ash and fly ash were measured and analyzed.The results indicate that the mass of PM1.0 and PM2.5 are 16.0%—17.4% and 46.9%—50.6% respectively.Na,Mg,P and S mainly enrich in submicron particles,and Al,Si,K,Ca,Ti and Fe mainly do in supermicron particles.With the decrease of particle size,the concentration of As,Cd,Cr and Pb increases,and the growth rate is higher for submicron particles than for supermicron particles,the concentration of Mn in different PM is similar.A large amount of As,Cd,Cr and Pb involves in the submicron PM,but Mn has no significant difference for different size PM particles.The volatileness of trace elements is As>Cd>Cr>Pb>Mn,and their emission factors under non-controlled conditions are listed in the paper.For PM1.0,the order of emission ratio of trace elements is the same as volatility,i.e.,As>Cd>Cr>Pb>Mn.