Studies on the Characteristics of Aerosol and Trace Metals Emitted from a CFB Coal-Fired Power Plant

徐鸿,骆仲泱,王涛,王鹏,高翔,施正伦,岑可法
DOI: https://doi.org/10.3321/j.issn:0253-2468.2004.03.026
2004-01-01
Abstract:The emission of primary particulates and trace toxic metals from coal-fired power plants is an important environmental issue. Experiments were performed in a 35?t/h circulating fluidized boiler (CFB) power plant, where particulate samples in flue gas were retained at the inlet and outlet of the ESP and segregated in a cascade impactor. Size-dependent capture efficiencies of the ESP to flue gas particulates were calculated, with an average of 94.3% for PM_(10) and 91.4% for PM_(2.5) respectively. Some fine particles were emitted to the atmosphere directly and formed primary inhalable particles. Concentrations of several trace metals were analyzed with furnace atomic absorption spectrometer (FAAS) after acid digestion. Size-dependent concentration distribution of flue gas particles and trace toxic metals were obtained at the inlet of ESP in a decreasing order of Ni,Cr,Cu,Cd,Pb,Hg. Trace heavy metals concentrations in flue gas particles were dependent both on particle size and specific element. Such characteristics were likely ascribed to the coal composition, combustion condition, element volatility during combustion.