Effect of the Angle Between Gas Flow Direction and Electrode on Single-Chamber SOFC Stacks

Yanting Tian,Zhe Lü,Zhihong Wang,Bo Wei,Xiang Guo,Pingping Wu
DOI: https://doi.org/10.1007/s10008-019-04266-w
IF: 2.747
2019-01-01
Journal of Solid State Electrochemistry
Abstract:Single-chamber solid oxide fuel cell (SC-SOFC) stacks with different angles between the gas flow direction and the electrode were fabricated and tested in a diluted methane-oxygen mixture. The gas tubes with separated gas vents were used for transmission of the reactant gasses. Experimental results showed that the performance of the two-cell stack at a gas flow angle ( θ ) of 45° was greatly enhanced compared with that at 0 and 90°. At a furnace temperature of 700 °C and a CH 4 /O 2 ratio of 2, the maximum output power of the anode-first configuration was 154 mW at θ = 45°, which was 51% higher than that obtained at θ = 90°. Additionally, the maximum power of the anode-first stack was higher than that of the cathode-first one at θ = 45°, which was contrary to the results obtained at θ = 90°. The stack with an angled configuration of θ = 45° will generate a more attractive power for portable power applications.
What problem does this paper attempt to address?