An Experimental Study on the Separation of Human Corneal Epithelium with Different Blade Edge Sharpness of the Ultra-thin Microkeratome

陈冲达,褚仁远,戴锦晖,周行涛
DOI: https://doi.org/10.3969/j.issn.1671-2420.2004.04.003
2004-01-01
Abstract:Purpose To study the effect of corneal epithelial separation with different blade edge sharpness(BES)of the ultra-thin mierokeratome and to investigate the suitable BES for the flap of corneal epithelium.Methods THe depth was 60 μm.The shaping of epithelial flap and sub-epithelial layer was observed and examined in histopathology.Results The corneal flap made with 80~100 gf BES of the microkeratome took good shape.Histopathological study showed the flap contained only epithelial layer without Bowman's membrane.And the basement membrane was intact.The corneal flap made with 70gf or under BES of the microkeratome also took good shape and was intact.Histopathological study showed it included not only epithelium,but also complete Bowman's membrane and a bit of corneal stroma.The corneal flap made with 110gf or mere edge degree of the microkeratome took bad shape and was incomplete.It was separated in the inner epithelium histopathologically.If the BES of the microkeratome was over 140 gf,it could not enter the cornea.Conclusion Corneal epithelial flap could be made with 80~100 gf BES degree of the ultra-thin microkeratome.