The Epithelial-Flap Abnormality of Laser Epithelial Keratomileusis

Xingtao Zhou,Liangcheng Wu,Jinhui Dai,Renyuan Zhu
DOI: https://doi.org/10.3760/j:issn:0412-4081.2002.02.003
2002-01-01
Abstract:OBJECTIVE:To investigate the technique of epithelial-flap performance and reposition and the factors related to the complication to improve the quality of laser epithelial keratomileusis (LASEK).METHODS:Fourteen eyes (9 cases) of epithelial-flap abnormality occurring in and after the operation in 309 eyes were observed and analyzed. The factors related to the abnormal flap were listed and discussed.RESULTS:The abnormal epithelial flaps of LASEK during and after the operation were free epithelial-flap, dissolution, fragments, fold, slip, and the late epithelial-flap abnormalities including epithelial defect and sub-epithelial foreign body 48 - 72 hours postoperatively. The related factors of complication included the shallow cut of micro-trephine, improper (too small) cut ring, improper concentration of alcohol, the invasion of alcohol solution, dry center of epithelial-flap, corneal epithelial injury by irrigation, and too early removal of contact lens.CONCLUSION:The epithelial-flap of LASEK is frailer than that of LASIK. The key point in the performance of a fine epithelial-flap is to manage every procedure carefully.
What problem does this paper attempt to address?