Experimental Research on Shear Performance of Reinforced Masonry Shear Walls of High Strength Concrete Blocks

全成华,唐岱新
DOI: https://doi.org/10.3321/j.issn:1000-6869.2002.02.012
2002-01-01
Abstract:Small-sized hollow concrete block,the most competent wall material for substituting brick than other wall materials,may be widely used to construct medium and high buildings in th e near future.The failure test of reinforced masonry shear wall with block strength above 20MPa and shear span over 1wa s conducted for the first time in Chin a.The experiment consisted of 7pieces of h igh strength cantilever shear walls reinforced respectively by longitu dinal and transverse steel bars under cyclic r eversed loading.The effects of vertical load,shear span ratio,transverse reinforce-ment on the lateral load-bearing cap acity were analyzed.Experimental r esults show that the failure mode of block shear wall is similar to those of cast-in-s ite concrete shear wall.The failure feature of reinforced masonry displ ays its charac-teristics for the function of transv erse steel bars.The fact that the num ber of cracks is more while the width o f the crack is small,and that the test specimen c racks rather than collapses during f ailure stage,all of which contribut ing to the improvement of aseismic performance,including strength,rigidity and energy dissipation capacity.In addition,the adaptability of the shear strength f ormulae of oblique section in the rev ised code for design of masonry structures(submitted for approval)are verified,and the tri-linear skeleton curve obtained from experimen t can serve as a base for time-history analysis of this type o f shear wall.
What problem does this paper attempt to address?