Experimental Study on Seismic Behavior of Steel Plate Reinforced Concrete Composite Shear Walls with Square CFST Concealed Columns

聂建国,胡红松,李盛勇,刘付钧,樊健生,陶慕轩,邵大成,喻德明
DOI: https://doi.org/10.14006/j.jzjgxb.2013.01.009
2013-01-01
Abstract:This paper presents experimental study on the seismic behavior of steel plate reinforced high-strength concrete composite shear walls with square concrete filled steel tube concealed columns.Three specimens with shear-span ratio of 2.0 and designed axial compression ratio of 0.5 were tested under cyclic loading.The variable parameters were concrete strength and steel ratio.The results indicate that the failure patterns of the tested walls includ fracture of the vertical weld between adjacent steel plates,crushing of the concrete in the concealed columns,local buckling of the outside steel plates.The exposed concrete in the middle of the tested walls don't crack seriously.All the three tested walls exhibite good hysteretic behavior and high energy dissipation capacity.The equivalent viscous damping coefficient at the ultimate state is about 0.22 for all the specimens.The average values of the yield drift angle,ultimate drift angle and ductility factor for the three tested walls are 1/214,1/58 and 3.77,respectively.The ratio of the top displacement due to flexure deformation and shear deformation kept nearly constant during the whole loading process,and the top displacement due to shear deformation is about 20% of the total top displacement.
What problem does this paper attempt to address?