Seismic behavior of composite shear walls incorporating high-strength materials and CFST boundary elements

Jianwei Zhang,Xiangyu Li,Wanlin Cao,Cheng Yu
DOI: https://doi.org/10.1016/j.engstruct.2020.110994
IF: 5.582
2020-10-01
Engineering Structures
Abstract:<p>An innovative shear wall was proposed, which was composed of high-strength concrete and steel rebars, as well as concrete-encased CFST columns embedded at boundary elements. To study the cyclic and resilient behavior of the proposed wall, four walls with shear span ratios of 2.2 were designed and tested under quasi-static cyclic loads. The test parameters were the type of longitudinal bars at boundary elements, the presence of steel fibers, and the axial compression ratio. As test results showed, within the limit of axial compression ratio, the proposed shear walls had small residual deformation until a 2% loading drift ratio; after that, the hysteresis curve became full and the energy dissipation capacity increased, indicating the desirable collapse resistance. Specifically, the use of ultra-high strength longitudinal bars at boundary elements significantly decreased the residual deformation and improved the reparability. In addition, steel fibers effectively enhanced the deformation capacity of the proposed walls. Finally, given the confined effects of CFST columns and stirrups on concrete, a prediction model for the lateral load-bearing capacity was established. The comparison between predicted and test results from this study and existing research verified the good accuracy of this model.</p>
engineering, civil
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to improve the performance and repairability of composite shear walls in earthquakes. Specifically, the research aims to enhance the seismic performance of composite shear walls by using high - strength materials (such as high - strength concrete and steel) and concrete - filled steel tubular (CFST) edge members. The following are the key issues mentioned in the paper: 1. **Repair Difficulties of Traditional Seismic Structures after Moderate - Strong Earthquakes**: Many earthquake disasters have shown that even if traditional seismic structures do not collapse after moderate - strong earthquakes, they may suffer severe damage and are difficult to repair. Usually, they need to be demolished and rebuilt, which brings huge demands for human and material resources. 2. **A Single Improvement Method Is Not Sufficient to Meet Seismic Requirements**: With the increasingly common application of high - strength concrete (HSC) in existing projects, a single improvement method (such as using high - strength steel bars, fiber - reinforced materials or steel structures) can no longer fully meet the seismic requirements of structures. 3. **Research Gap in Composite Shear Walls**: At present, there is relatively little research on the cyclic and ductile behavior of composite shear walls containing high - strength materials and concrete - filled steel tubular (CFST). Therefore, it is necessary to fill this research gap. To solve these problems, the researchers proposed an innovative composite shear wall, which is composed of high - strength concrete and high - strength steel bars, and has concrete - filled steel tubular (CFST) columns embedded in the edge members. Through quasi - static cyclic load tests, the seismic performance and repairability of four shear walls with different parameters were studied, and the effects of factors such as the type of longitudinal steel bars, the addition of steel fibers, and the axial compression ratio were analyzed. Finally, a prediction model for lateral bearing capacity was established and its accuracy was verified. ### Main research contents include: - **Design and Experiment**: Four shear wall specimens were designed, and their seismic performance was studied through quasi - static cyclic loading experiments. - **Material Properties**: The mechanical properties of high - strength concrete and steel bars were described in detail. - **Testing Devices and Instruments**: The settings of experimental devices and measuring equipment were introduced. - **Experimental Results and Analysis**: Hysteresis curves, skeleton curves, strength and stiffness degradation, energy dissipation capacity and strain distribution were analyzed. Through these studies, the paper aims to provide theoretical basis and technical support for the development of composite shear walls with good seismic performance and repairability.