Experimental study and finite element analysis of seismic behavior of sprayed concrete sandwich shear walls

钱稼茹,宋晓璐,冯葆纯,张以超,王海宁
DOI: https://doi.org/10.14006/j.jzjgxb.2013.10.002
2013-01-01
Abstract:To study the seismic behavior of sprayed concrete sandwich shear walls, quasi-static tests on seven specimens were carried out. The main parameters of specimens were wall thickness and boundary element. The test results indicate that the two-layer or three-layer concrete and their reinforcements of the sandwich shear wall work together to carry the vertical compressive force and the lateral loads. The specimens have two types of failure mode, i.e. compression-flexure failure and shear failure. Increasing the vertical reinforcement at the boundary elements leads to shear failure for specimens. The lateral force-displacement hysteretic loops of specimens have a certain extent of pinching. The ultimate drift ratios of specimens failed in compression-flexure are 1/76-1/103, and the ultimate drift ratio of the specimens with boundary elements is 1.3 times that of the specimens without boundary elements. Increasing the wall thickness has no effect on the ultimate drift ratio. The energy dissipation capacity of specimens failed in shear is smaller than that of the specimens failed in compression-flexure. The shear strength and the compressive-flexure strength of specimens can be calculated by current code formulas for concrete shear walls. The MSC Marc (2010) based non-linear finite element analysis results of the specimens, such as lateral force-displacement skeleton curves, crack patterns and load-carrying capacities are in good agreement with the test results.
What problem does this paper attempt to address?