Local Measurement of Bubbly Flow in Helically Coiled Tubes Using Double-Sensor Conductivity Probe
Yichuan Huang,Nan Gui,Xingtuan Yang,Jiyuan Tu,Shengyao Jiang,Hongye Zhu
DOI: https://doi.org/10.1080/00223131.2020.1720846
IF: 1.126
2020-01-01
Journal of Nuclear Science and Technology
Abstract:The two-phase flow in helically coiled tubes (HCTs) is rather important in many industries, such as the heat exchange facility in nuclear power plant. In this work, a double-sensor conductivity probe was used to study the air/water bubbly flow in HCTs. The cross-sectional distribution profile of the interfacial parameters (void fraction, interfacial area concentration, bubble size, etc.) of air-water bubbly flow were systematically studied. Through carefully processing the raw data collected by the double-sensor conductivity probe, the distribution of the void fraction, interfacial area concentration, the bubbles number frequency over the cross-section are demonstrated, as well as the bubble velocities and sizes vertically in the dense region. Some statistical parameters of cross-sectional-averaged quantities, coefficients of variation, and bubble aggregation core coordinates are defined to quantitatively describe the distribution characteristics of interfacial parameters. The measured data are helpful for improving the understanding of two-phase flow characteristics in HCTs.