Measurement and Correlation for Heat Transfer Coefficient in Bubble Column with Vertical Pipe Bundles

LI Hong-bo,ZHANG Yu,WANG Li-jun,LI Zhao-qi,LI Xi
DOI: https://doi.org/10.3969/j.issn.1003-9015.2012.03.006
2012-01-01
Abstract:The radial distributions of heat transfer coefficient h were measured with heat transfer probes in a 500 mm× 5000 mm bubble column without and with internals of 31 vertical pipe bundles in it,respectively.The experiments show that the heat transfer coefficient h increases with the increase of the superficial gas velocity,and the h distributions exhibit parabolic profiles along the radial direction.It was found that the vertical internals in the column increase the gradient of h distribution profiles.Based on the surface renewal model and combined with the computation on radial distribution of gas holdup and liquid velocity,a novel heat transfer model was developed to correlate the radial distributions of h under conditions of with and without vertical pipe bundles.The model developed is a unified one which can be used to calculate both the average and local heat transfer coefficients for all the situations of with and without vertical pipes.The values of h predicted by the developed model were compared with the experimental values,and the results show that the predicted h values agree well with the experimental data with a difference of less than 5.62%.This indicates that the proposed model has a strong prediction capability.
What problem does this paper attempt to address?