A New Method for Void Fraction Measurement of Gas-Liquid Two-Phase Flow Based on C~4D Technique

常亚,黄志尧,王保良,冀海峰,李海青
2014-01-01
Journal of Engineering Thermophysics
Abstract:Based on Capacitively Coupled Contactless Conductivity Detection(C~4D) technique,a new method for void fraction measurement of gas-liquid two-phase flow is proposed.The research work includes two parts:First,a new six-electrode C~4D sensor is designed.Second,as a preliminary research,experiments are carried out for void fraction measurement of gas-liquid two-phase flow(stratified flow) by the new six-electrode C~4D sensor.The experiment results show that the application of C~4D technique to void fraction measurement of gas-liquid two-phase flow is feasible,the developed six-electrode C~4D sensor is effective,and the C~4D technique is prospective to provide an effective method to implement the void fraction measurement of gas-liquid two-phase flow.
What problem does this paper attempt to address?