Experimental Study on Purification of Odorous Gases from Wastewater Treatment Plant by Biological Deodorization Towers

Xing-chun DAI,Min-sheng HUANG,Dao-fang ZHANG
DOI: https://doi.org/10.3321/j.issn:1000-4602.2007.13.003
2007-01-01
Abstract:The self-designed biological deodorization towers were used to purify odorous gases from a wastewater treatment plant.The effect of inoculated activated sludge on improvement of deodorization efficiency was introduced.The influence of external conditions and operation mode on deodorization efficiency was analyzed.The result shows that when the retention time of odorous gases is 60 s,the purification effect is relatively ideal.The removal rates of NH3 and H2S by No.1 tower with inoculated activated sludge reach 89% and 90% respectively,and those of No.2 tower without inoculated activated sludge are 81% and 79%,which shows that the inoculated activated sludge can promote the purification of the odorous gases.The 60 s retention time of odorous gases is the most economic and reasonable.The optimal retention time of the circulating liquor is 3.5 to 4 h.The optimal pH is 5 to 7 for NH3,and 3 to 5 for H2S.The result also shows that only 68% and 38% NO2 are removed by the both towers due to too low concentration of NO2 in inlet gases,which means that the removal effect of too low-concentration odorous gases remains to be further improved.