Design Case of Odor Removal Project in Dye Industrial Zone's Wastewater Treatment Plant

Wei SHEN,Yun-song WU,Dong-yu LU,Qiang ZHANG,Wei LI
DOI: https://doi.org/10.19853/j.zgjsps.1000-4602.2017.12.014
2017-01-01
Abstract:The design of odor removal project in dye industrial zone's wastewater treatment plant in Changzhou City was introduced in this paper.After the odor source was located,different sealing methods were adopted depending on the wastewater treatment constructions characteristics.The equalizing tank,primary setting tank and sludge concentrated tank was sealed by the inverted membrane with carbon steel skeleton so that the direct contact between the steel and the odor gas could be avoided.With this seal method,the mud scrapers in primary setting tank and sludge concentrated tank could rotate with the carbon steel skeleton-membrane structure.And then,the seal volume could be reduced.All odor gas was delivered to the biofilter via fiberglass pipes after the odor source was sealed.After the project was com pleted,the monitoring results from biofiher outlet and disordered discharge places indicated that the pollutants in all samples could meet the requirements of odor in Emission Standards for Odor Pollutants (GB 14554-1993).
What problem does this paper attempt to address?