ODOR DISPOSAL EFFECT OF TRANSFER STATION WASTE WATER BY ANAEROBIC-COAGULATION-ADVANCED OXIDATION

Ye Bin,Jiang Jianguo,Chen Aimei,Wu Jialing
DOI: https://doi.org/10.13205/j.hjgc.2012.02.034
2012-01-01
Environmental engineering
Abstract:The effect of transfer station waste water odor treatment by each unit was analyzed.The pilot scale system was based on anaerobic-coagulation-advanced oxidation.Total reduced sulfur(TRS) was taken as indexes.The amount of TRS was 0.602 mg/L in transfer station waste water.After treatment by the units of anaerobic-coagulation-advance oxidation,the values turn into 4.167,3.513 and 0.168 mg/L.Anaerobic degradation of sulfur-contained organic compounds was an important process of odor material generation.Coagulation showed little effect on waste water odor removal.Removal rate of odor material by advanced oxidation was over 95 %,comparing to effluent of coagulation.