An UV photo-oxidation system for treatment of malodorous gas from wastewater treatment plant

KONG Xin,WANG Can,XI Jinying,HUA Jianliang,CHENG Zhiqiang,JI Min
DOI: https://doi.org/10.7524/j.issn.0254-6108.2013.01.002
IF: 4.236
2013-01-01
Environmental Chemistry
Abstract:An UV photo-oxidation system was used to treat malodorous gas generated from the aerated grit channel in a sewage wastewater treatment plant.The effects of empty bed residence time(EBRT),influent odorants concentration and UV irridiation intensity on removal performance and ozone production in the system were investigated.The kinetics of odorant removal and ozone production were also analyzed.The experimental results show that the average removal efficiencies of H2S and NH3 were 34.3% and 53.8% when the respective primary concentration was 35 mg·m-3 and 0.26 mg·m-3 under the condition of EBRT=1.5 s,average ultraviolet radiation intensity UV=1664 μW·cm-2.The removal rates of H2S and NH3 by the UV-photo-oxidation system increased linearly with UV intensity and finally maintained at the highest value.The ozone production rate in the system mainly decreased linearly with influent odorant concentration and increased with UV intensity up to a certain value.Moreover,the kinetic analysis demonstrates that the mathematical expressions built in this research can quantitatively describe the effects of influent odorant concentration and UV irradiance on odor removal and ozone production rates.
What problem does this paper attempt to address?