COMPARISON BETWEEN UV/O_3-BAC AND O_3-BAC FOR TREATMENT OF ORGANIC POLLUTANTS IN THE EFFLUENT FROM SEWAGE TREATMENT PLANT

ZHANG Peng-yi,ZHANG Qiu-yun
2008-01-01
Abstract:A new combined technological process of light-supporting ozonation oxidation-biological activated carbon(UV/O3-BAC) was used for treatment of secondary effluent from municipal sewage treatment plant to investigate the effects of ozone dosages,oxidation reaction time and the BAC retention time on effluent quality.It was showed that the TOC removal rate increased with the increases of ozone dosage,oxidation reaction time,and the BAC retention time;its optimal technological parameters were ozone dosage 3 mg/L;both time 15 min for oxidation reaction and BAC staying at empty tower.At the optimal parameters,the average removal rate of TOC and UV254 by UV/O3-BAC process reached to 46% and 71% respectively,rising by 35.3% and 14.5% respectively,in comparison with these by sole O3-BAC process;the both processes possessed synergetic action on organics removal,in it,the synergetic effect of UV/O3-BAC was more obvious than that of O3-BAC process;UV/O3 and O3 both processes turned the macromolecular organics in water into small molecules to improve the effluent bio-degradability,thus being advantageous to removal of organic pollutants by follow-up BAC.