Advanced Treatment of Incineration Leachate with O3-BAC and Double O3-BAC

An-jing Du,Ju-hong Fan,Rui Liu,Song-kai Qiu,Xiao-gang Wen,Lü-jun Chen
DOI: https://doi.org/10.13227/j.hjkx.2015.11.028
2015-01-01
Abstract:Ozone-biological activated carbon (O3-BAC) process and double O3-BAC process were respectively used for advanced treatment of the biologically treated effluent of incineration leachate, and their pollutant removal performances were compared. The results showed that the double O3-BAC removed 75.9% ± 2.1% of chemical oxygen demand (COD), 78.8% ± 2.9% of UV254 and 96.8% ± 0.9% of color at ozone dosage of 200 mg x L(-1). The treated effluent was with COD of below 100 mg x L(-1) and color of below 40 times, meeting the emission requirements of GB 16889-2008. At the same ozone dosage, however, the O3-BAC removed 68.2% ± 1.3% of COD, 69.7% ± 0.5% of UV254 and 92.5% ± 1.1% of color. The treated effluent was with COD of around 150 mg x L(-1) and color of about 60 times, failing to meet the emission requirements. Namely, ozone of 290 mg x L(-1) was required by O3-BAC in order to achieve similar pollutant removals as those in double O3-BAC at O3 dosage of 200 mg x L(-1). In double O3-BAC at ozone dosage of 200 mg x L(-1), total phosphorus was removed by 63.5% ± 4.4%, and the phosphorus concentration in the effluent was remained 1 mg x L(-1) or less, directly meeting the emission requirement of GB 16889-2008.
What problem does this paper attempt to address?