Comparison of O3-BAC and GAC for Removing Micropollutants from Drinking Water

Shaomei Zhang,Beihai Zhou,Chunhong Shi,Zhansheng Wang
DOI: https://doi.org/10.1109/mace.2010.5535965
2010-01-01
Abstract:Studied was the comparison of ozone-biological activated carbon (O3-BAC) and granular activated carbon (GAC) processes for advanced drinking water treatment. The effects by O3-BAC and GAC were evaluated based on the removal of the indexes including CODMn, UV254, TOC, BDOC, NH4+-N, NO3--N and NO2--N. The results showed that the treatment effect by O3-BAC was better than that by GAC alone. When ozone dose was at its optimal level 2.0mg/L, the removal efficiencies of CODMn, UV254 and TOC by O3-BAC were 15.1%, 17.4% and 16.2% respectively higher than that by GAC alone. Furthermore, BDOC removal by O3-BAC process was four times as much as that by GAC process. The NH4+-N and NO2--N of O3-BAC effluent were both lower than that of GAC alone. Ozone increased the lower molecule weight organic compounds capable of being easily adsorbed by activated carbon and improved the biodegradability of the organic matters in the water so as to strengthen the biological treatment capability for organic pollutants by the subsequent treatment units.
What problem does this paper attempt to address?