Fate of Organic Pollutants in a Full-Scale Drinking Water Treatment Plant Using O3-BAC

Anan Song,Xiang Liu,Yan Liu,Lihui Lyu,Luming Ma
DOI: https://doi.org/10.1080/01919512.2014.997867
2015-01-01
Abstract:This research investigated the fate of organic pollutants in each unit of a full-scale O-3-BAC (biological activated carbon) drinking water treatment plant with micro-polluted raw water under different temperatures. Total organic matters were largely removed with low DBPs (disinfection by-products) formed. Large molecules were broken into smaller ones by O-3 and middle-sized ones totally removed. Concentration of polysaccharide decreased except under high temperature. Small molecule contaminant species of refractory industrial additives, hydrocarbons, aromatics, herbicides, possible DBPs, etc., were detected. Some species passed through treatment process, some were removed and also new species formed.