Advanced treatment of Lurgi Gasifier coaI gasification wastewater by ozonation-BAC process

Yulong Tan,Yeran Li,Jie Tang,Fengjun Xu,Wei Zheng,Ljun Chen,Ying Li
2016-01-01
Abstract:T he combined process,ozonation-BAC has been applied to the advanced treatment of wastewater from Lurgi Gasifier coal gasification. The main factors influencing the treatment efficiencies are studied ,and the steady running effectiveness of the system is investigated. The results show that the optimum removing rates of CODCr,chro-ma and UV254 of the wastewater in ozonation occur when ozone generator current is 0.5 A and bipolar reaction column ozone dosage volume ratio=2∶1. Pollutants removal could be benefited from extending the hydraulic retention time of BAC appropriately. During stable operation period,wastewater CODCr can averagely be reduced from 298 mg/L to 57 mg/L,and average COD removing rate is 81%. The removal of NH3-N and TN depends on nitrification and denitrifi-cation of biofilm in BAC filter. The average removing rates of NH3-N and TN are 26%and 37%,respectively.