Modeling of Stress Transfer at the Interface of the Cemented Prosthesis and Femur

YU Xue-zhong,HE Rong-xin,GUO Yi-mu
2009-01-01
Abstract:Objective To study the modeling stress transfer at the interface of cemented prosthesis and femur.Methods assuming that the prosthesis,the cement and the femur are concentric cylinders made of linear elastic and isotropic materials. The axisymmetric interfacial stress transfer model considering thermal effect is established,distribution of axial stress of the prosthesis,the cement and the femur,distribution of the interfacial shear stress at the prosthesis-cement interface and at the cement-femur interface in axial direction is obtained.Results Interfacial failure is the main failure form of prosthesis-cement-femur structure under the external load. Under the effect of residual thermal stress,it's more likely to produce the mixed failure form but not the pure shear failure form. Since the cement has a relatively high thermal expansion coefficient,the existence of thermal effect accelerates the interfacial failure and then aggravates the stress shielding effect. Under a relatively high thermal residual temperature difference,the cobalt-chromium alloy prosthesis material is more likely to lead to the interfacial and femur failure than the Ti-6Al-4V alloy prosthesis material.Conclusion When the prosthesis bears the compress stress,assuming that the prosthesis,the cement and the femur are concentric cylinders made of linear elastic and isotropic material,by using the basic equations of axisymmetric elastic mechanics,the distribution of axial stress of the prosthesis,the cement and the femur,the interfacial shear stress at the prosthesis-cement interface and at the cement-femur interface in axial direction were obtained. Interfacial failure is the main failure form of prosthesis-cement-femur structure under the external load. The existence of thermal residual temperature difference accelerates the failure and the destroy of the prosthesis-cement interface and the cement-femur interface,accelerates the relaxation of the prosthesis,aggravates stress shielding effect of the femur.The main reason for this is that the cement has a relatively high thermal expansion coefficient. The elastic modulus and the thermal expansion coefficient of Ti-6Al-4V material are smaller than that of cobalt-chromium alloy material. The existence of thermal effect decreases the efficiency of interfacial stress transfer,but to a certain degree it alleviates the failure of the interface and the femur,which is unanimous with the clinical findings.
What problem does this paper attempt to address?