The Biomechanical Study of Intertrochanic Fractures Treated with Cemented Femoral Stem

YU Xiao,ZHANG Hai-jun,YAN Shi-gui,YU Guang-rong
DOI: https://doi.org/10.3969/j.issn.1008-0392.2010.05.011
2010-01-01
Abstract:Objective To study the biomechanical stability of the communited intertrochanic fracture treated with cemented standard femoral stem prosthesis.Methods Twelve cadaveric femurs were selected in this study and divided into two groups randomly.The experimental group was simulated as communited intertrochanic fractures at four parts while the control group was simulated as the femoral neck fractures.Both groups were treated with cemented femoral prosthesis following standard hemiarthroplasty procedure and the four parts fractures in experimental group were fixed by wires additionally.The specimens were tested mechanically by universal testing machine through vertical and rotational loading.The displacement of the prosthesis while applying the loading were recorded and the differences of displacement magnitudes between two groups were analyzed.Results No significant differences of displacement were found between two groups either in vertical loading from 100N to 1000N or in rotational loading from 100N to 800N.Conclusion The use of femoral stem prosthesis is biomechanically acceptable in the treatment of intertrochanic fractures.
What problem does this paper attempt to address?