The changes in cement stress are affected by cement-mantle thickness in total hip arthroplasty: a theoretical analysis

Haobo WU,Shigui YAN,Shice YU
DOI: https://doi.org/10.3969/j.issn.1006-2785.2007.09.010
2007-01-01
Abstract:Objective To investigate cement stress after total hip arthroplasty (THA) using a validated mathematical analytical models. Methods Changes in cement stress in the proximal femur following implantation can be estimated by composite beam theory. In the validated mathematical models, the proximal femur was divided into eleven equidistant cross sections; each section was further divided into four quadrants corresponding to the anterior, posterior, medial and lateral aspects of the femur. Two sections (55mm and 105mm from femoral head center) were used to calculate. Cement stress levels were evaluated when cement-mantle thickness changed from 0 to 4.0mm. And cement stress values were calculated when cement thickness changed by 0.1mm. Results In posterior quadrant of 105mm section, periprosthetic bone stress decreased with the mantle thickness from 1.5mm to 4.0mm. And cement stress decreased with the mantle thickness from 3.0mm to 4.0mm. In other quadrants and all 55mm section quadrants, cement stress were increased with cement-mantle thickness added. Conclusion Cement crack numbers and crack growth rate might not depend on cement-mantle thickness directly, but on cement stress. Cracks in thin mantles reached the full thickness of mantle soon not by the higher cement stress but the poor thickness. These cracks may be related to the stem aseptic loosening.