Thermal Performances of Two Stage Molten Salt Steam Generator

Canming He,Jianfeng Lu,Jing Ding,Weilong Wang
DOI: https://doi.org/10.1016/j.egypro.2017.03.432
2017-01-01
Energy Procedia
Abstract:Thermal performances of two stage molten salt steam generator were experimentally investigated in this article. The two stage system consisted of primary U shape heat exchanger and secondary shell and tube heat exchanger, and its overall heat transfer coefficient, steam generation rate and thermal efficiency were further analyzed under different molten salt flow rates and water flow rates. According to the experimental results, the overall heat transfer coefficients of the primary and secondary heat exchanger both increase as the molten salt flow rising. As the water flow rate increases, the overall heat transfer coefficient of the primary heat exchanger first increases and then decreases, while that of the secondary heat exchanger gradually increases. As the molten salt flow rate and water flow rate increase, the steam generation rate and the thermal efficiency of the secondary heat exchanger both increase, while the thermal efficiencies of the primary heat exchanger and the whole system first increase, approaching their maximums with optimal molten salt flow rate and water flow rate respectively, and then begin to drop.