Analysis of Ejection-Cooling at the Shut-off Operating Condition for a Reheat Fuel Centrifugal Pump

FAN Hongyu,LU Qizhi,GONG Jingsong,PIAO Ying
DOI: https://doi.org/10.16511/j.cnki.qhdxxb.2016.22.029
2016-01-01
Abstract:The high fuel temperature rise at the shut-off operating condition in a reheat fuel centrifugal pump is addressed by cooling the impeller by fuel flowing through a by-pass from the pump inlet.The ejection-cooling is analyzed using the Reynolds average Navier-Strokes (RANS) method with the shear stress transport (SST) turbulence model and the Rayleigh Plesset cavitation model.The results show that the ejection-cooling design can reduce the high fuel temperature rise at the shut-off condition.The power consumption and the friction heat are both reduced in the reheat fuel centrifugal pump with the ejection-cooling device because of the vapor core region in the impeller central zone which reduces the fuel temperature rise.
What problem does this paper attempt to address?