Research Of Fault-Tolerant Strategy For Power Converter Of Four-Phase Dsem Drive

Doudou Hu,Bo Zhou,Zhiwei Gan,Xuzhen Huang,Xingwei Zhou
2016-01-01
Abstract:Power converter open-circuit fault leads to reduction of motor output performance. Fault-tolerant control strategy, which is applied to power converter of four-phase doubly salient electro-magnetic motor (DSEM) drive, is investigated in this paper to improve the post-fault motor performance. A fault-tolerant topology is newly presented. It has the advantage of simple structure with only two bidirectional switches added to four-phase full bridge converter. Based on the presented topology, fault-tolerant control process contains four steps, including fault detection, faulty arm isolation, bidirectional switch triggering and switching states adjustment. The proposed fault-tolerant control strategy is able to obtain the average output torque nearly as that of normal operation, which is proved by the co-simulation results of Maxwell and Simplorer. Finally, experimental results demonstrate the correctness and feasibility of the proposed fault-tolerant control strategy.
What problem does this paper attempt to address?