Fault Tolerant Control of a Multiphase Motor with Non-Sinusoidal Source under Open-Phase Conditions

KONG Wu-bin,HUANG Jin,KANG Min,LI Bing-nan,GENG Ze-yang
DOI: https://doi.org/10.3969/j.issn.1007-449x.2013.05.002
2013-01-01
Abstract:Multiphase motors commonly adopt concentrated windings and non-sinusoidal sources in order to improve the flux distribution as well as torque density.A strategy for fault tolerant control under phase-open fault is proposed due to the characteristics of multiphase motor.Taking a 9-phase induction motor for example,the equations of currents for the remaining phases were derived,which is based on the principle that the stator magnetic motive force(MMF) is kept unchanged after the fault occurrence.The remaining phase currents commands were solved when the copper losses were minimized by neglecting the 7th harmonics of stator MMF,only keeping 1st,3rd,5th harmonics unchanged.Proportional resonant control strategy was adopted in the current loop,to achieve zero ac current error in the stationary frame.In the end,experimental results shows improved torque density and smoothed torque ripple,which validates the proposed strategy.
What problem does this paper attempt to address?