Mechanical Properties of Zircaloy-4 Cladding Tube by Advanced Expansion Due to Compression (A-Edc) Test

Z. Zhao,D. Kunii,T. Abe,H. L. Yang,S. Kano,Y. Matsukawa,Y. Satoh,H. Abe
DOI: https://doi.org/10.2320/matertrans.ml201601
2017-01-01
MATERIALS TRANSACTIONS
Abstract:A new testing technique named advanced expansion due to compression (A-EDC) has been developed with an attempt to study the hoop mechanical behavior of Zircaloy-4 cladding under the pellet-cladding mechanical interaction (PCMI) and the presumed reactivity-initiated accident (RIA). The Zircaloy-4 used in this work showed elongated grains in the tube longitudinal direction, large amounts of residual strain, and crystallographic texture. The finite element method (FEM) analysis illustrates that the A-EDC test shows a uniaxial tension in the hoop direction, which has also been confirmed by experiments. In addition, the hoop stress-strain curve has been derived at room temperature by the A-EDC tests. Moreover, the fractured surface has been observed in this research.
What problem does this paper attempt to address?