Shaping ability of R-phase nickel-titanium rotary instruments in simulated S-shaped canals

Xiao-mei HOU,Tong-fei SHAO,Ben-xiang HOU,Zheng SU
2015-01-01
Abstract:Objective To evaluate the shaping ability of TF,Endo Wave and K3 instruments in simulated Sshaped root canals. Methods A total of 120 simulated S-shaped resin blocks were divided randomly into three groups( n= 40),each group was prepared with each instrument,respectively. Preparation time was recorded. Pre-and postoperative images were obtained by a digital microscope and superimposed using Photoshop. The change of curvatures,and material removal from the inner and outer canal walls at 10 points beginning from 0 mm at the end point of the canal were measured using Image J. Centering ability was determined,accordingly. The data were analyzed using the One-Way ANOVA at a significance level of P 0. 05. Results Preparation time for TF was 14. 00 ± 4. 56 s,significantly faster than that for K3 and Endo Wave,while the changes of curvatures were not significantly different among the three instruments. At the apical curve,the removal of resin from the inner wall by TF was significantly less than Endo Wave and K3( P 0. 05). At the coronal curve,the material removal from the outer wall of TF were significantly less than K3( P 0. 05). At the straight part,TF removed significantly less material from the inner wall than Endo Wave and K3( P 0. 05). At points from 5 mm to 9 mm,the transportation of TF were significantly less than Endo Wave( P 0. 05),while that of TF was not significantly different with that of K3( P 0. 05),except for the 6 mm point( P 0. 05). Conclusion TF prepares S-shaped resin canals efficiently,with less aberrations and transportations than Endo Wave and K3.
What problem does this paper attempt to address?