Influence of Operational Modes in Lightening the Membrane Fouling in Submerged Membrane Bio-Reactor

张颖,吴亿宁,任南琪
DOI: https://doi.org/10.3969/j.issn.1005-9369.2003.03.006
2003-01-01
Abstract:Lagre-scale application of Membrane Bio-Reactor is conditioned by membrane fouling which is a bottle-neck problem.The influence of operational modes in lightening the membrane fouling was studied in this paper.The results indicated that the average increase of membrane flux of back washing module B was 22.30% relative to control module A.The tests for operational modes proved that back washing operation could help pollutants (with the lesser combined power) to fall off and help membrane modules to hold quite longer life.Auto-back washing system could be adopted in practical engineering according to work condition.At the same time,the mechanism of aeration preventing membrane from contamination was discussed in detail.The stereo and planar graphs of membrane module structure units were presented.
What problem does this paper attempt to address?