Influence factors on membrane fouling in a submerged MBR for treatment of high strength organic wastewater

王颖,黄霞,袁其朋
DOI: https://doi.org/10.3969/j.issn.1007-8924.2004.01.001
2004-01-01
Abstract:A submerged membrane bioreactor was used to treat high strength organic wastewater.Influences of suction time,membrane flux and mixed liquid characters on membrane transfer resistance,which was used as an indicator of membrane fouling in the present study,were investigated.At the same aeration amount,MLSS concentration of about 13 g/L and cease time of 3 min,the proper suction time was 10 min,membrane flux was 10 L/(m~2·h).Based on experimental results,a quantitative relationship between membrane transfer resistance R_(20) at operating time of 20 minutes,SS concentration and supernatant COD of mixed liquor was deduced as R_(20)=9.129E(+9)*COD~(0.449 7)SS~(1.018 9).Sludge cake layer on the outer membrane surface and bio-fouling on the inner membrane surface were the main reasons of membrane fouling.
What problem does this paper attempt to address?