Operating Characteristics of Submerged Membrane Bioreactor at Sub-critical Flux

魏春海,黄霞,赵曙光,文湘华
DOI: https://doi.org/10.3321/j.issn:1000-4602.2004.11.003
2004-01-01
Abstract:Critical region for two membrane modules was measured by using flux step-wise method,and then the operating characteristics at sub-critical were investigated.It is found in experiment that the membrane fouling at sub-critical is characterized by two stages with two stages trans-membrane pressure (TMP) profile being observed.The gradual rise of TMP for the first stage is due to the fouling caused by membrane pore blocking and gel layer.The rapid rise of TMP for the second stage is due to the fouling by cake layer.Flushing with tap water followed by chemical cleaning is able to restore the membrane filtration capacity,with tap water flushing for removing effectively the fouling by cake layer and chemical cleaning for efficient removal of fouling by membrane pore blocking and gel layer.
What problem does this paper attempt to address?