Membrane Contamination Control in the Intermittent Aeration Mode of Operation of the C-MBR Process for Campus Wastewater Reuse

Ruoting Gao,Ronglin Sun,Chunfang Zhang,Wenjie Zhang
DOI: https://doi.org/10.3390/w15234144
IF: 3.53
2023-11-29
Water
Abstract:Filtration backwashing is necessary for the effective operation of membrane modules, and intermittent aeration helps to remove nutrients, which can save energy and effectively control the occurrence of membrane contamination. In this study, membrane contamination was controlled using an MBR in intermittent aeration operation mode and a filtration backwash cycle; difficult organic matter and nitrogen (COD and NH4+-N) were used as the main contamination indicators for this study; and the main membrane contamination components, extracellular polymers (EPs), and soluble microbial products (SMPs) were detected. The results show that the average removal of COD and NH4+-N could reach 86.45% and 92.47%, respectively, with a 2.0 day intermittent aeration time and 9/1 min filtration backwash cycle mode, and it also helped to reduce the membrane contamination, as shown by a decrease of 11.87% in bound EPs (EPSBound) and an increase of only 5.32% in SMPs. Microbiological analyses revealed that Proteobacteria and Acinetobacter, as dominant bacteria (50.90%), were the main causes of membrane contamination.
environmental sciences,water resources
What problem does this paper attempt to address?