Design and operation of an A/O-MBR process for campus sewage treatment and reclamation

Feifei Li,Yan Zhang,Lüjun Chen,Ying Li,Wei Li,Jianguo Li,Mancheng Zhao,Qiyuan Lü
2013-01-01
Abstract:An A/O-MBR process with the capacity of 1 500 m3/d was employed aiming at the reclamation of sewage in a university, and the water quality monitoring and economic analysis were conducted in the long-term operation. The MLSS of the MBR was maintained between 8 g/L to 12 g/L. The HRT of the anoxic tank and the aerobic tank was 3 h and 7 h, respectively, and the sludge return ratio was 200%~300%. When the average influent concentration of COD, total nitrogen and ammonia nitrogen were 481.3, 75.1 and 65.8 mg/L, respectively, the average effluent concentration of COD, total nitrogen and ammonia nitrogen were 16.5, 13.4 and 0.7 mg/L, and the corresponding removal efficiency were 96.4%, 81.9% and 99.0%, respectively. The chemical phosphorus removal was achieved with the PAC coagulation, the effluent concentration of total phosphorus was 0.8 mg/L and the average removal efficiency was 86.5%. The water quality is better than that of the National Water Quality Standard for Urban Miscellaneous Water Consumption (GB/T 18920-2002). The economic analysis showed that the electicity cost of the systerm is 0.58 kWh/m3.
What problem does this paper attempt to address?