Treatment of pharmaceutical wastewater for reuse by coupled membrane-aerated biofilm reactor (MABR) system
hailong tian,huimin zhang,peng li,linquan sun,feifei hou,baoan li
DOI: https://doi.org/10.1039/c5ra10091g
IF: 4.036
2015-01-01
RSC Advances
Abstract:The high-concentration pharmaceutical intermediate wastewater treatment was studied experimentally by using a coupled membrane-aerated biofilm reactor (MABR) system, which included ozone oxidation as pretreatment, MABR biochemical method, and improved coagulation-flocculation technology as post-treatment. First, the influence of ozone production rate and reaction time on chemical oxygen demand (COD) reduction and biochemical oxygen demand (BOD5)/COD (B/C) ratio was explored. 53% COD reduction and an increase of B/C ratio from 0.22 to 0.46 were achieved under the conditions of 6 g h(-1) of dose and 30 min of reaction time. Subsequently, multi-group continuous experiments were conducted to investigate the effect of hydraulic retention time (HRT), aeration pressure, and flow velocity on C and N removals in MABR system. With 24 h HRT, aeration pressure of 0.15 MPa, and flow velocity of 0.08 m s(-1), 95% COD removal and 92% total nitrogen (TN) reduction were obtained simultaneously in the MABR process. Finally, the improved coagulation-flocculation was applied using polyaluminium chloride (PAC, 1.2 g L-1) combined with polyacrylamide (PAM, 2 mg L-1) and magnetic powder (8-10 g L-1) to generate excellent effluent quality for industrial reuse in China (GB/T 19923-2005). In conclusion, O-3-MABR-improved coagulation/flocculation technology was feasible for treating pharmaceutical intermediate wastewater for reuse.