A Study on the PVC Membrane Fouling in MBR and Its Cleaning Method

De-tao LIU,Tao XUE,Xia HUANG,De-ping XU
DOI: https://doi.org/10.3969/j.issn.1009-6094.2008.03.018
2008-01-01
Abstract:The paper is inclined to investigate the PVC ultrafiltration membrane fouling course in a submerged membrane bioreactor so as to find a desirable cleaning method. In doing so,we have tested two operation modes of no-backwash and weekly-backwash using low mass concentration NaClO solution (available Cl mass concentration is 500 mg/L) through comparison and contrast under sub-critical flux condition of 15 L/(m2·h). It was found that the increasing rates of trans-membrane pressure rates obtained should be equal to 1.23 kPa/d and 0.97 kPa/d,respectively. What is more significant is that the cleaning method using NaClO solution (mass fraction is 3×10-3) is expected to be the best as compared with other on-line cleaning methods,including extended aeration,water cleaning,HCl solution (pH=1) and NaOH solution (pH=12) cleaning. Besides,compared with other various off-line chemical cleaning methods,the sequential NaClO solution (mass fraction is 3×10-3) and HCl solution (pH=1) cleaning method proves to be the most suitable.
What problem does this paper attempt to address?