Study on effect of membrane fiber length on critical flux in a novel membrane bioreactor

BU Qingjie,ZHU Hongtao,WEN Xianghua,HUANG Xia
DOI: https://doi.org/10.3321/j.issn:0253-2468.2008.03.006
2008-01-01
Abstract:Critical flux plays an important role in the control of membrane fouling in membrane bioreactors.Experiments were conducted to determine the critical flux region of four membrane modules with different membrane fiber lengths,under different aeration intensity.The results show that:① the membrane module with a membrane length of 0.4 m had the highest critical flux region(compared to 0.2 m,0.6 m and 0.7 m)at the same aeration intensity;② critical flux improved as the aeration intensified in the same membrane module.The influence of membrane fiber length on critical flux mainly occurs through two mechanisms:the flux distribution along the membrane fiber and the fiber shaking effect due to aeration.According to the results simulated from a flux distribution function,the non-uniformity of flux along a membrane fiber increases with the membrane fiber length,leading to a lower critical flux.The longer the membrane module(fiber)is,the bigger the air bubbles are that are formed under the same aeration intensity,and also the easier for the membrane fiber to shake and vibrate which reduces the deposition of foulant onto the membrane surface,and therefore a higher critical flux is reached