MEMBRANE FOULING CONTROL BY DUAL AERATION MODES IN MBR

Jing LI,Hong HE,Jia-hui CAO,Chao CHEN,Xu-dong FENG
DOI: https://doi.org/10.13205/j.hjgc.201804013
2018-01-01
Environmental engineering
Abstract:The effects of different aeration modes on membrane fouling were studied in membrane bioreactor.Results showed that:The membrane resistance decreased according to the increase of the pore size when single-mode microporous aeration was applied in the membrane bioreactor,while the membrane resistance decreased according to the increase of the difference in pore size when dual-mode microporous aeration(two tubes) was applied,the greater the distance between the aeration tube and the membrane module was,the more serious the membrane fouling was.When dual-mode microporous aeration(three tubes)was applied in the membrane bioreactor,the position of the tubes should be optimized to decrease the membrane fouling.The best aeration combination was dual mode (three tubes) aeration with 1 μm + 10 μm + 1 μm,the membrane fouling resistance was0.834 ×1012 m-1.
What problem does this paper attempt to address?