Combination of Hot/Cold Wires for Non-Isothermal Flow Measurements

刘明侯,张先锋,陈义良,蔡晓丹
DOI: https://doi.org/10.3969/j.issn.1001-4888.2004.01.010
2004-01-01
Abstract:With a cold-wire placed in close proximity to the hot-wire, combination of hot and cold wire technique was applied to study non-isothermal flow field. A method to overcome temperature contamination of velocity probe was suggested. The temperature measured by cold wire was used to compensate the velocity reading of a hot-wire probe, the response of the hot-wire can be broken down into the respective velocity and temperature components and corrections to the output signal can be applied before conversion to a true velocity. The percentage difference between true velocity ,U_∞, and the corrected flow velocity, U, were presented. It is demonstrated that this correcting method can achieve acceptable accuracy over a limited velocity range (0.5~5m/s) while altering fluid temperature range from 10℃ to 80℃. On the other hand, combination of hot- and cold-wire technique can provide us not only mean velocity and its fluctuations,but also mean temperature, its fluctuations and streamwise heat flux information of the flow field. With the help of this technique, the simultaneous measurements of instantaneous velocity and temperature in a vertical pipe were carried out to study buoyancy effects on flow characteristics. This compensation method is recommended to study non-isothermal flow field, especially the field with strong temperature fluctuation and/or mean temperature gradient.
What problem does this paper attempt to address?