Experimentation of the X-ray Elliptical Crystal Spectrograph

肖沙里,唐跃林,熊先才,钟先信,高洁,杨国洪
DOI: https://doi.org/10.3321/j.issn:1004-924x.2004.04.012
2004-01-01
Abstract:Based on the theory that is ray emitted from a focus (front) of an ellipse will converge on the other focus (back) by the reflection on the elliptical surface, the Elliptical Crystal Spectrograph (ECS) in the X-ray region of 620~6 200 eV was designed. The principle of the system was analyzed,and the design and manufacture were accomplished. KAP,LiF,PET and MiCa are used as dispersive elements covering Bragg angle from 30° to 67.5°. The crystal sizes are 120×8×0.2 mm with the curved analyzer substrate of eccentricity e=0.958 6, focal distance of 1 350 mm,and optical path length of 1 456 mm. The analyzer of the elliptical profiles was machined into a suitable substrate material using a Computer-Controlled milling machine. The Elliptical Crystal Spectrograph was experimented on Shanghai Shenzhou Ⅱ with laser energy of 150 J,laser wavelength of 0.35 μm,and chamber vacuum level 3×13~(-3) Pa. To achieve optical alignment with a small point source,an aligned telescope was precisely fitted to the elliptical analyzer block. The result shows that spectra of Au target can be measured in 0.63~0.709 nm with a resolution of 1/486(△λ/λ). It is found that the resolution of the spectrograph depends on the rocking curve and the thickness of the crystal and the laser spot diameter. In addition,ECS is simpler and easier to use,with a higher collecting efficiency and a better resolution. It can effectively obtain abundant information of the laser-plasma emission spectra in an inertial confinement fusion.