An Industrial Experimental Research on Combustion Denitrification of Fujian Anthracite in CFB Boiler

何宏舟,骆仲泱,俞建洪,邹峥,方梦祥,岑可法
DOI: https://doi.org/10.3969/j.issn.1005-006x.2004.05.019
2004-01-01
Abstract:An denitrification experiment was conducted in a 75t/h industrial CFB boiler whose fuel is Fujian anthracite. It was shown from the experiment that: (1) with the increasing of the excess air coefficient (a), the NOx emission in flue gas would decrease; But when a was greater than 1.3, the NOx emission would increase at first with the growing of a and then tended to keep in a steady level; (2) the NOx emission would decrease with the raising of secondary air coefficient when the total excess air coefficient (a) was hold constant; for those CFB boiler whose fuel was fujian anthracite, it was found that there existed an optimal secondary air coefficient , which would make the NOx emission converted from the Fuel-nitrogen lowest; (3) under the same operating condition, for CFB boiler burning Fujian anthracite with high nitrogen content, the NOX emission in flue gas was also higher.
What problem does this paper attempt to address?