Abstract:Using limestone as desulfurizing agent, an industrial experiment was conducted on a 35 t/h CFB boiler whose fuel was Fujian anthracite. The effects of the variation of Ca/S (ratio in mol) and Mean Sizes of Limestone's Particle (MSLP) on the desulfurization results were tested. It was shown from the experiment that: (1) Both the time-average desulfurisation efficiency and the maximum instantaneous desulfurisation efficiency would increase with the rise of Ca/S molar ratio, but the increasing-pace was slow when Ca/S < 2.5. A 53% time-average desulfurization efficiency and a 77% of the maximum instantaneous desulfurization efficiency could be obtained when Ca/S ratio reached 3.15; (2) The desulfurization efficiency would be higher when the MSLP was smaller. when Ca/S ratio was 2.91 and the MSLP was 0.36 mm, the times-average desulfurization efficiency could approximate to 50%; (3) Due to a relatively lower desulfurization efficiency, adding limestone to combustion would reduce the furnace's thermal capacity, thus cause a slightly descending in boiler's thermal efficiency.