Abstract:The load-bearing lightweight steel structure is built by welding tr ansverse and inclined lace bars on longitudinal chords, which is called the spat ial steel frame. The concrete structure with spatial steel frame is gained by su bstituting spatial welding steel frame for binding steel skeleton in reinforced concrete structure. In order to study the seismic behavior of concrete short col umn with spatial steel frame, including its bearing capacity, deformation capabi lity, ductility as well as failure mechanism, the comparison of the tests of 3 c oncrete columns with spatial steel frame and 1 reinforced concrete column subjec ted to low cyclic reversed load are carried out. The results of the tests showed that the initial stiffness of the concrete column with spatial steel frame is a lmost the same as that of the reinforced concrete column. The stiffness degradat ion of the concrete column with spatial steel frame is slower than that of the r einforced concrete column after yielding of the specimen. Under the same conditi ons, the ductility of the concrete column with spatial steel frame is better tha n that of the reinforced concrete column. The spatial steel frame bearing constr uction loads and directly hanging formwork must be calculated by two stage desig n method recommended in this paper. Based on the tests and analysis, the detaili ng requirements of such structure are presented.