An Improved Phase-Robust Configuration for Vibration Amplitude-Phase Extraction for Capacitive MEMS Gyroscopes

Xudong Zheng,Siqi Liu,Yiyu Lin,Haibin Wu,Lai Teng,Zhonghe Jin
DOI: https://doi.org/10.3390/mi9070362
IF: 3.4
2018-01-01
Micromachines
Abstract:This paper presents for the first time an improved algorithm for vibration amplitude-phase information extraction of capacitive microelectromechanical systems (MEMS) gyroscopes. Amplitude and phase information resulting from the improved algorithm is insensitive to the phase variation of an interface capacitance-voltage (CV) circuit, thus both long time drift of the gyroscope and bias instability have been improved. Experimental results show that both the phase and amplitude information extracted using this improved algorithm is insensitive to phase variation of CV circuit which is in accordance with theory. Bias instability using this improved configuration is 0.64°/h, which is improved two times more than the configuration using traditional double-side-band (DSB) demodulation configuration, and 4.3 times more than the configuration using single-side-band (SSB) demodulation, respectively. Allan deviation analysis shows that the slow varying drift term using D&S configuration is effectively reduced due to its robustness to CV phase variation compared to test results using DSB or SSB configuration.
What problem does this paper attempt to address?