Far-forward Collective Scattering Measurements by FIR Polarimeter-Interferometer on J-TEXT Tokamak.

P. Shi,J. Chen,L. Gao,Y. Liu,H. Liu,Y. N. Zhou,G. Zhuang
DOI: https://doi.org/10.1063/1.4960067
IF: 1.6
2016-01-01
Review of Scientific Instruments
Abstract:The multi-channel three-wave polarimeter-interferometer system on J-TEXT tokamak has been exploited to measure far-forward collective scattering from electron density fluctuations. The diagnostic utilizes far infrared lasers operated at 432 μm with 17-channel vertical chords (3 cm chord spacing), covering the entire cross section of plasma. Scattering laser power is measured using a high-sensitivity Schottky planar diode mixer which can also detect polarimetric and interferometric phase simultaneously. The system provides a line-integrated measurement of density fluctuations with maximum measurable wave number: k⊥max ≤ 2 cm-1 and time response up to 350 kHz. Feasibility of the diagnostic has been tested, showing higher sensitivity to detect fluctuation than interferometric measurement. Capability of providing spatial-resolved information of fluctuation has also been demonstrated in preliminary experimental applications.
What problem does this paper attempt to address?