Forward Scattering Measurement Based on Terahertz Microwave Interferometer on KTX Reversed Field Pinch

Wenzhe Mao,Jinlin Xie,Sen Zhang,Luxiuyuan Jiang,Tao Lan,Hong Li,Adi Liu,Ge Zhuang,Weixing Ding,Wandong Liu
DOI: https://doi.org/10.1109/tps.2019.2908180
IF: 1.368
2019-01-01
IEEE Transactions on Plasma Science
Abstract:Electron density fluctuation has been measured based on the collect forward scattering method using a single-chord microwave interferometer system on the Keda Torus eXperiment (KTX) reversed field pinch. The interferometer system is a heterodyne one with two terahertz solid-state sources with frequency around 650 GHz, and the transmitted beam and forward scattering beam are received simultaneously by a Schottky planar diode mixer with sensitivity about 500 mV/mW. Constrained by the beamwidth and geometry limitation, the measurable wave vector range is k(w) <= 5 cm(-1) with a resolution Delta k approximate to 2.07 cm(-1). MHD activities are detected via this forward scattering technique. The results are consistent with other diagnostics, such as the chord averaged electron density, the edge magnetic probe, and high-speed charge-coupled device (CCD) camera.