Non-inductive Vertical Position Measurements by Faraday-effect Polarimetry on EAST Tokamak.

W. X. Ding,H. Q. Liu,J. P. Qian,D. L. Brower,B. J. Xiao,J. Chen,Z. Y. Zou,Y. X. Jie,Z. P. Luo,X. Z. Gong,L. Q. Hu,B. N. Wan
DOI: https://doi.org/10.1063/1.5035280
IF: 1.6
2018-01-01
Review of Scientific Instruments
Abstract:Vertical instability control in an elongated plasma is highly desirable for a tokamak reactor. A multi-channel 694 GHz far-infrared laser-based polarimeter-interferometer system has been used to provide a non-inductive vertical position measurement in the long-pulse EAST tokamak. A detailed comparison of vertical position measurements by polarimetry and external inductive flux loops has been used to validate Faraday-effect polarimetry as an accurate high-time response vertical position sensor.
What problem does this paper attempt to address?