Design of a Multi-Channel POlarimeter-INTerferometer System Based on Terahertz Solid-State Diode Sources on EAST

C. Xu,Z. Y. Zou,J. B. Zhang,S. X. Wang,B. Hong,C. L. Lan,X. D. Pan,H. Q. Liu
DOI: https://doi.org/10.1109/irmmw-thz50927.2022.9895936
2022-01-01
Abstract:Plasma position plays a critical role in fusion plasma performance, and any loss of the plasma position control is not acceptable for safe fusion device operations. To maintain a high temperature plasma, the plasma should not touch the wall of the vacuum chamber and be confined in the magnetic field. So studying fast and accurate plasma position measurement technique is very necessary. Traditional measurement methods are affected by discharge duration, high temperature and electromagnetic interference. The plasma position can also be measured by Faraday-effect polarimeter as a non-inductive position sensor with fast time response. In this work, a multi-channel Vertical POlarimeter-INTerferometer (V-POINT) based on 0.65 Thz solid-state diode sources (SSDS) for horizontal plasma position measurements on the EAST tokamak has been designed. The optical design and bench test results of the V-POINT on EAST will be presented.